beautypg.com

Chapter 2 installation – Grass Valley PRS 250 RAID Storage System User Manual

Page 30

background image

Chapter 2 Installation

2-12

RAID Instructions

Setting an SP’s SCSI ID

The Profile will support two separate external file systems. The RAID Storage chassis
is an external attachment which can be assigned SCSI IDs 8 through 15.

If the RAID units are configured as two external file systems, the first unit or pair of
units of the second file system must be set to SCSI ID 12. If only a single RAID is to
be used, it should be assigned the lowest SCSI ID available. See the following two
examples.

EXAMPLE 1: Two RAIDs daisy-chained to a Profile with a single external SCSI
bus would have SCSI IDs 8 & 9.

EXAMPLE 2: Six RAIDs attached to a Profile with two external SCSI buses
(three daisy-chained RAIDs to each bus) would have SCSI IDs 8, 9, & 10 on each
bus
.

NOTE: RAID units should be attached symmetrically to the two buses (that is, the
same number of RAIDs on each bus with the same number of disk modules in each
chain).

ID 0
ID 1
ID 2

ON

ID 3

ID 0
ID 1
ID 2
ID 3

SP B

SCSI ID

SP A

SCSI ID

Back of storage chassis

SCSI ID

Switch number

number

ID 0

ID 1

ID 2

ID 3

0

On

On

On

On

1

Off

On

On

On

2

On

Off

On

On

3

Off

Off

On

On

4

On

On

Off

On

5

Off

On

Off

On

6

On

Off

Off

On

7

Off

Off

Off

On

8

On

On

On

Off

9

Off

On

On

Off

10

On

Off

On

Off

11

Off

Off

On

Off

12

On

On

Off

Off

13

Off

On

Off

Off

14

On

Off

Off

Off

15

Off

Off

Off

Off

This manual is related to the following products: