Chapter 3 Servicing the System

3-16

RAID Instructions

Emergency Procedures (without an ESD kit)

In an emergency when an ESD kit is not available, use the following procedures to
reduce the possibility of an electrostatic discharge by ensuring that your body and the
subassembly are at the same electrostatic potential.

CAUTION: These procedures are not a substitute for the use of an ESD kit. Follow
them only in the event of an emergency.

• Before touching any electronic circuits or boards inside the equipment, firmly

touch a bare (unpainted) metal surface of the equipment.

• Before removing any replacement or upgrade subassembly from its antistatic bag,

place one hand firmly on an unpainted metal surface of the chassis, and at the same
time, pick up the replacement or upgrade subassembly while it is still sealed in the
antistatic bag. Once you have done this, do not move around the room or contact
other furnishings, personnel, or surfaces until you have installed and secured the
subassembly in the equipment.

• Remove the subassembly from the antistatic bag, handling printed circuit boards

by the edges. Avoid touching components and circuits on a printed circuit board.

• If you must move around the room or touch other surfaces before securing the

subassembly in the equipment, first place the subassembly back in the antistatic
bag. When you are ready again to install the subassembly repeat these procedures.

Precautions When Removing, Installing, or Storing CRUs

When removing or installing a CRU, never use excessive force. If you have difficulty
removing or installing a CRU, read the procedures again. Once you have removed a
CRU, handle it gently because a sudden jar or drop could permanently damage it.

Your replacement or add-on CRU is sent to you in a specially designed shipping
container. Store the CRU in this container, and use this container if you need to return
the CRU for repair. The storage location of a disk module, SP, VSC module, or fan
module must be maintained within the non-operating limits specified in Appendix A