Two-channel pdr200/one dual-sp raid, Two-channel pdr200/one dual-sp raid -16 – Grass Valley PRS 250 RAID Storage System User Manual
Page 34

Chapter 2 Installation
2-16
RAID Instructions
Two-Channel PDR200/One Dual-SP RAID
This configuration, see the following illustration, consists of a two-channel PDR200
(one Master Disk Recorder - MDR) connected to a single RAID chassis with two SPs.
1. Connect a SCSI-2 cable from the Profile MDR rear panel connector (SCSI-A) to
the RAID chassis SCSI A IN connector.
2. Connect a SCSI-2 cable from the PDR200 SCSI-B rear panel connector to the
RAID chassis SCSI B IN connector.
3. Connect a SCSI terminator plug to the RAID chassis SCSI A OUT connector.
4. Connect a SCSI terminator plug to the RAID chassis SCSI B OUT connector.
0226-3
RAID Chassis
2-Channel Profile Disk Recorder
J10
SCSI B
SCSI-2 Terminator
SCSI-2 Cable
This manual is related to the following products: