80
Connections Window
Connections Window
Viewing Diagnostic Crosspoint Data
The ‘Connections’ window displays either XY/standard (video or audio), XY/mono, or machine
control crosspoint lists. The lists are often displayed in tabbed viewing panes or “tabs.”
The following is a list of what tabs are viewable for each router:
•
NV5100MC
—
standard and mono tabs.
•
NV5128
—
standard, mono, and machine control tabs.
•
NV5256
—
machine control tab.
•
NV7256 and NV7256-Plus
—
standard and mono tabs.
•
NV7512
—
standard and mono tabs.
•
NV8256-Plus
—
standard tab only.
•
NV8288 and NV8288-Plus
—
standard tab only.
•
NV8500 Family
—
standard tab only.
Output follow crosspoints must be explicitly enabled. An output follow crosspoint list is a re-
interpretations of the XY/standard, XY/mono, or machine control list you are viewing. The inter-
pretation allows you to specify output follow connections rather than perform takes.
How to View Crosspoints
1 Select a control card.
2 From the ‘Window’ menu, choose ‘Connections’. The ‘Connections’ window appears. The
crosspoint list is empty.
3 If you are viewing the crosspoints of an NV5100MC, NV7256 or NV7512, click the ‘X-Y/Stan-
dard’ tab or the ‘X-Y/Mono’ tab to bring it to the front. If the mono tab is in front, the window
will show controls appropriate for mono signals.