Viewing configurations, How to view current configuration settings – Grass Valley UniConfi NVISION Series v.2.1 User Manual
Page 19

7
UniConfig
User’s Guide
•
EM0529
—
The NV8288 and the NV8288-Plus use this control card. Connect to the rear diag-
nostic port of the router frame. There are two ports. Use the one for the control card you
want to configure. (Both control cards must eventually be configured identically.)
The connection is RS-232, 38400 Baud, 8N1.
•
EM0666
—
This card is used by NV8500 family standard routers. Connect to the rear diagnos-
tic port of the router frame. There are two ports. Use the one for the control card you want to
configure. (Both control cards must eventually be configured identically.)
The connection is RS-232, 38400 Baud, 8N1.
See
on page 17 for complete details.
The control cards on a router must be configured separately and identically.
Viewing Configurations
After you have connected to a control card, go to the ‘Configuration’ window.
How to View Current Configuration Settings
1 Select a control card.
2 Go to the ‘Configuration’ window:
Fig. 3-1: Configuration Window (NV8256 Sample)
3 Click Read All. Current configuration data populate the ‘Configuration’ window.
If ‘Auto Refresh’ is enabled, it is not necessary to click Read All. See
Automatic Refresh
on
page 15.