45

UniConfig

User’s Guide

In NV9000-SE Utilities, there is not “output follow” virtual level type. You’ll need to define a phys-
ical level of the same type as the outputs being followed with the same level number you
defined in UniConfig. In this example, that is level 77. Then define a virtual level that maps to
this new physical level.

Cascading Outputs

In the scenario of example 2, suppose the operator takes 30 to 31 on the output follow level and
then takes output 1 to output 30 on the output follow level.

Then the operator takes input 20 to output 1. Input 20 appears simultaneously on outputs 1, 30,
and 31.

The operator can create multiple “cascading” output follow states by issuing the appropriate
takes on the output follow level.

The operator can clear the output follow states by routing to those outputs on a normal level.