EC9535

EC9535

How to Set Up Partitions for an EC9535

1 Select a control card.

2 From the ‘Window’ menu, choose ‘Configuration’. The ‘Configuration’ window appears:

3 Click Read All. The ‘Configuration’ window populates with the current configuration and

Ethernet settings. If no prior configuration is stored, many of the fields are blank.

4 Create a level.

To do so, enter ‘Level’, ‘Physical Inputs’, ‘Controller Inputs’, ‘Physical Outputs’ and ‘Controller
Output’ information in the grid at the top of the window. Each row represents a level.

The EC9535 has only one partition. The level number must be 0 to be compatible with the
requirements of the SMS7000.

The following is a list of the fields and the values you should enter (for an EC9535):

These values are appropriate for the SMS7000 control system.

5 Click Write All to writes changes to the control card.

6 Repeat steps 1–5 for the other EC9535 control card.

UniConfig Field

Description

Values

Level

Numeric value identifying the partition.

0

Physical Inputs

Starting and ending physical input connector numbers.

1–1024

Controller Input

Starting logical input connector number. The ending num-
ber is derived.

1

Physical Outputs

Starting and ending physical output connector numbers.

1–1024

Controller Output

Starting logical output connector number. The ending
number is derived.

0

Signal Type

Acceptable signal types for the partition

‘Video, Async,
AES, Timecode’