Name adapters – Grass Valley K2 Summit Client Service Manual Nov.23 2009 User Manual
Page 56

56
K2 Summit Production Client Service Manual
12 October 2009
Chapter 3 Service Procedures
5. Repeat the previous steps until you have a determined which “Intel® PRO/1000 PT
Dual Port Server Adapter…” name goes to which (PCI bus X, device 0, function
X) location.
6. Continue with the next procedure
.
Name adapters
1. If you have not already done so, disable the write filter.
2. If you have not already done so, on the Windows desktop right-click
My Network
Places
and select
Properties
.
The Network Connections window opens.
In the Device Name column you see the adapter names and enumerators that the
Windows operating system has assigned to adapters.
3. Determine which adapter names in the Device name column are assigned to which
(PCI bus X, device 0, function X) location.
4. Reconcile the locations assigned to the adapter names with the names as currently
configured in the Name column.
Intel® PRO/1000 PT Dual Port Server Adapter #4
PCI bus ____, device 0, function ____
On this K2 Summit Client, Windows has
assigned this adapter name…
To this location: