H3C Technologies H3C MSR 50 User Manual
Page 131

The following parameters that reflect VoIP network performance can be calculated by using the metrics
gathered by the voice operation:
•
Calculated Planning Impairment Factor (ICPIF)—Measures impairment to voice quality in a VoIP
network. It is decided by packet loss and delay. A higher value represents a lower service quality.
•
Mean Opinion Scores (MOS)—A MOS value can be evaluated by using the ICPIF value, in the
range of 1 to 5. A higher value represents a higher service quality.
The evaluation of voice quality depends on users' tolerance for voice quality, which you should consider.
For users with higher tolerance for voice quality, use the advantage-factor command to configure the
advantage factor. When the system calculates the ICPIF value, it subtracts the advantage factor to modify
ICPIF and MOS values, so both objective and subjective factors are considered.
The voice operation requires both the NQA server and the NQA client. Before you perform a voice
operation, configure a UDP listening service on the NQA server. For more information about UDP
listening service configuration, see "
."
A voice operation cannot repeat.
To configure a voice operation:
Step Command
Remarks
328.
Enter system view.
system-view
N/A
329.
Create an NQA operation
and enter NQA operation
view.
nqa entry admin-name
operation-tag
By default, no NQA operation is
created.
330.
Specify the voice type and
enter its view.
type voice
N/A
By default, no destination IP
address is configured.
331.
Configure the destination
address of voice packets.
destination ip ip-address
The destination IP address must be
the same as that of the listening
service on the NQA server.
By default, no destination port
number is configured.
332.
Configure the destination port
of voice packets.
destination port port-number
The destination port must be the
same as that of the listening service
on the NQA server.
Optional.
codec-type { g711a | g711u |
g729a }
333.
Specify the codec type.
By default, the codec type is
G.711 A-law.
Optional.
334.
Configure the advantage
factor for calculating MOS
and ICPIF values.
advantage-factor factor
By default, the advantage factor is
0.
118