Encoder Firmware User

’s Manual H1.02.30

65

example is a “panic button”, which always stays in inactive mode “0” until the button is pressed;

when the button is pressed, its active level becomes “1” which means the DI is triggered. Active

level “1” returns back to “0” (inactive mode) after the specified

Interval

. The

Interval

is the

duration of time when the trigger remains in active mode which is also the minimum time interval

between the previous trigger and the next. For example, if the interval is set to

“5 seconds”, the DI

will

not respond if the “panic button” is pressed within 3 seconds after the previous trigger. To

issue another trigger, click the button after 5 seconds from the previous trigger.

DO

: To configure the digital output device, define the active level and response interval. The

default

Active Level

is “1”, which means the DO will turn to active mode and respond once

triggered. The duration of its response will last according to the set

Interval

. A good example is

an alarm siren, wherein the siren will start sounding only when it is triggered by an event or

another device like a DI. The siren will stop sounding once the set interval time elapsed.

After changing any of the items above, click

Apply

to save the changes. The Reset button

undoes the changes that had just been made but not yet applied or saved.

Setting Configurable DI/DO Ports (for V23 / V24 only)

There are four (4) DIO ports for V23 and V24 models. These DIO ports can be configured to

either DI or DO on the

I/O

column. Every video channel can have up to 4 DIs and 4 DOs. Check

the channel number box on the

Channel

column to assign a video channel for that port.

A DO port is automatically associated to every video channel thus the channel numbers on

Channel

are automatically checked for the port that is set as DO.

Digital I/O Ports Section of V23 / V24

By default, the

Active Level

of each ports are “0”, which means the DI/DO device will remain

inactive unless triggered. The duration of its response will last according to the set

Interval

.

After changing any of the items above, click

Apply

to save the changes. The Reset button

undoes the changes that had just been made but not yet applied or saved.