Bit inversion mask, Crc recognition, Crc table – Wavecom W-SPECTRA (Automatic Monitoring System) V1.1.0 User Manual
Page 53: Clear screen

WAVECOM Monitoring System W-SPECTRA, W-SPEED Manual V1.1.0
Parameters and Options
43
Bit Inversion Mask
One or several data bits may be inverted by using the Bit Inversion item.
The Bit Inversion Mask can be entered in three different ways:
In the top input box a decimal number between 0 and 31 may be entered
In the center input box the same number may be entered in binary format with the least signifi-
cant bit to the right
In the bottom check boxes a logical "1" is entered with the mouse by clicking in the check box
Bit Inversion is only implemented for ITA-2 (Baudot) based bit streams.
CRC Recognition
An automatic detection of the CRC can be switched on/off with CRC.
CRC Table
A table of CRC's is stored as \Config\CRCTable.xml. The user may open and edit this xml file by clicking
the “Edit” button beside the “CRC” parameter.
Clear Screen
There is a “Clear” button right to the result display window. Click this button to clear the screen, all the
output in the display window will be deleted.
A “Clear” screen button.