Classifier code check sequences, Classifier modulation settings – Wavecom W-SPECTRA (Automatic Monitoring System) V1.1.0 User Manual
Page 219
WAVECOM Monitoring System W-SPECTRA, W-SPEED Manual V1.1.0 Classifier
– the Brain of W-SPECTRA
209
Classifier Code Check Sequences
From this list, the desired mode of operation of the CCC is selected. Each process performs one or more
steps to narrow down the possible candidates for eventual successful signal determination or decoding.
The availability of more or less complex processes allows the user to select the process which is best suit-
ed to his purposes.
The process selected is shown in the status line.
Process
Steps
P1
Only classification is performed, but no decoding.
P2
Classification and table check are performed, but no decoding.
P3
Classification, table check and code check are performed, but no decoding.
P4
Classification and table check are performed and finally the signal is decoded if a mode with an associat-
ed, valid detector was found.
P5
Classification, table check and code check are performed and finally the signal is decoded if a mode with
an associated, valid detector was found.
Classifier Modulation Settings
These settings control the behavior of the classifier. See the section on “
” on page 206 for details. Note that the Refresh List option is not available when the
classifier is used with the CCC.