beautypg.com

Wavecom W-SPECTRA (Automatic Monitoring System) V1.1.0 User Manual

Page 227

background image

WAVECOM Monitoring System W-SPECTRA, W-SPEED Manual V1.1.0 Classifier

– the Brain of W-SPECTRA

217

Baud Rate [Bd]

or Symbol Rate [Bd]

Enter the channel rate in Bd. For two-condition signals, e.g., FSK, PSK-2 or
CW, the baud rate equals the bit rate including channel coding overhead if
any. For two-condition signals without any overhead, the baud rate equals
the user or source bit rate.

Codecheck Count

The number of times the code check must be executed to obtain the desired
confidence level.

Comments

A user free text field.

Decoder

Enter the WAVECOM decoder mode used by the CCC. Selected from a drop-
down list of available modes.

Name

The name given to the table entry by the user. This field is a free text field.

Modulation

The modulation method used by the decoder. Set by default or selected from
a drop-down list of modulation methods available for the selected decoder.

ITU Designator

A user free text field for the ITU emission designator applicable to this signal.

Minimum No. of Carriers The minimum number of carriers in a multi-carrier system.

Minimum No. of Chan-
nels

The minimum number of channels in a VFT system.

Minimum No. of Tones

The minimum number of tones in a multi-frequency system.

No. of Carriers

The number of carriers in a multi-carrier system.

No. of Channels

Number of channels in a VFT system.

No. of Tones

The number of tones in a multi-frequency system.

Pilot Frequency [Hz]

If applicable, the frequency of the system pilot frequency, pilot tone or Dop-
pler correction tone.

Recognition disabled

If checked the signal is not included in the CCC recognition process and the
record is greyed out in the list of records.

Shift [Hz]

The frequency shift for two-frequency FSK.