Frame relay port statistics screen, Frame relay port statistics screen -32 – Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual
Page 64

3-32
W A N s u i t e 5 1 6 0 / 5 1 3 0
Tx Alarm
Status of this alarm indicates OK or Alarmed.
Rx Threshold
Number of bits per second sent during a 15-minute interval after which an Rx
alarm will be triggered. Default of 0 disables this alarm.
Rx Alarm
Status of this alarm indicates OK or Alarmed.
The Frame Relay Details screen provides the following user-activated buttons:
NOTICE:
When a “Submit” command is executed, the Frame Relay link will be
re-initialized with the new parameters, causing a brief interruption in
data transfer.
Frame Relay Port Statistics Screen
Clicking the “Frame Relay Statistics” button brings up a table (Figure 3.26)
that reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field on the Frame Relay
Service Details screen and clicking the “Submit” button.
Button
Function
Submit
Sets any values that have been changed.
Frame Relay Statistics
Opens the Frame Relay Port Statistics screen for the current
Frame Relay service.
DLCI Table
Opens the DLCI Table screen, which displays all the DLCIs
on the current service. Refer to DLCI Table Screen on
page 3-50 for more information.
Clear Alarms
Clears all Frame Relay alarms.