Ds0 monitor details screen (5160 only), Ds0 monitor details screen (5160 only) -24 – Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual
Page 56

3-24
W A N s u i t e 5 1 6 0 / 5 1 3 0
Figure 3.20
Confirm Delete Service Screen
DS0 Monitor Details Screen (5160 Only)
To access the DS0 Monitor Details Screen (Figure 3.21), click on “TDM” in
the Type column on the Service Details screen. This screen lets you configure
what are considered high and low DS0 utilization parameters, and will report
alarms if the monitored statistics rise above or fall below those specified
settings. This helps determine customer load patterns so that channel
bandwidth can be reallocated as necessary.
Figure 3.21
DS0 Monitor Details Screen
Number of DS0s
Number of active DS0s (0
−
24) assigned on a per-service basis.
Alarm Reset Timer
(sec)
Number of seconds that an alarm condition must not be present before an
alarm is reset. Zero (0) indicates the Alarm Reset Timer is disabled.
Values: 0
−
900
Default: 30
High Utilization %
Lets you configure as a percent what is considered high utilization.
Values: 1
−
100
Default: 100