Notice – Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual
Page 236

5-18
W A N s u i t e 5 1 6 0 / 5 1 3 0
Figure 5.17
Serial 1 and Serial 2 (5160) or Serial (5130)
Configuration Menu Tree
Use the SERIAL 1 CONFIG and SERIAL 2 CONFIG (5160) or the SERIAL
CONFIG (5130) to set the configuration parameters defined in the following
paragraphs. On the WANsuite 5160, the submenus and options are the same
for both SERIAL 1 CONFIG and SERIAL 2 CONFIG menus.
Type
This parameter selects the type of interface (based on its electrical signal
characteristics) used by the equipment connected to the Serial port.
Values: V.35, RS-232, EIA-530
Default:V.35
NOTICE:
V.35 requires the use of an optional cable. Refer to Optional Equipment
on page A-6 for ordering information.
Mode
By default, the Serial port serves as a DCE port in both Packet and TDM
modes. However, the Serial port can serve as a DTE port when the unit is in
Packet mode.
If the Serial port connects to a DTE device (such as a FRAD or a router), the
Mode parameter must be set to “DCE.” If this port connects to a DCE device
(such as a DSU/CSU), this parameter must be set to “DTE” (valid only for
Packet mode, not TDM).
Values: DCE, DTE
Default:DCE
NOTICE:
DTE mode requires the use of an optional DTE cable. Refer to
Appendix A,"Specifications," for ordering information.
V.35
RS-232
EIA-530
Serial 2
Configuration
Type
Mode
DSR
DCD
CTS
RTS
RTS Delay
Tx Clock
DCE
DTE
True
False
Int
True
False
Int
True
False
Int
Normal
True
Normal
Long
Int
Ext
Nx56K
Nx64K
(N = 1–32)
Channel
Rate
Rate
Inv Clock
Bundling
Start
Channel
No. of
Channels
V.54
LL
DTR Alrm
Nx64K
Nx56K
Cont
Alt
1–24
1–24
Dis
En
Dis
En
Dis
En
Dis
En
Serial 1
Configuration