W e b S e r v e r I n t e r f a c e
3-13
Bundling
Selects whether the DTE channel assignment is made as a “Contiguous”
group or as “Alternate” channels. Selecting “Alternate” ensures ones density.
Because the unit allows individual channels to be configured for a service, a
value of “Arbitrary” will be returned for this parameter if the current channel
allocation is not contiguous or Alternate. The “Arbitrary” value can only be
supplied by the unit
−
it cannot be set by the user.
Values: Contiguous, Alternate, Arbitrary
Default: Contiguous
NOTICE:
Because “Alternate” Bundling assigns every other channel, only half
the channels are available.
Start Channel
Selects the starting channel in the 24-channel DS1 bit stream. Starting with
the specified channel, the unit automatically assigns the channels that follow.
Values: 1 through 24
Default: 1
Number of Channels
Specifies the number of channels to be assigned to the DTE.
Values: 0 through 24
Default: 24 Channel Rate
Channel Rate
The unit can operate at any data rate that is a multiple of 56 or 64 kbps. If
“
Ν
x64K” is selected, the ones density requirements of the T1 network line
must be ensured. If “
Ν
x56K” is selected, ones density for the selected DS0
channel is maintained.
Values: Nx56K, Nx64K
Default: Nx64K
NOTICE:
Start Channel, Number of Channels, and Channel Rate cannot be
changed if Bundling is not also changed from “Arbitrary.”
Invert Clock
In DTE Packet mode, this parameter changes the clock edge of the
transmitted data. The Invert Clock parameter is only available for use in DTE
mode, and DTE mode is only available for the Serial 2 port. Consequently,
this configuration option only works for the Serial 2 port, and should remain
disabled when configuring services for the Serial 1 port.
Values: Disable, Enable
Default: Disable
Character Size
Selects the number of bits required to make up one asynchronous character.
Values: Five, Six, Seven, Eight
Default: Eight
Tx Clock
Selects the clock the unit uses to sample the data transmitted from the DTE.
When set to “Internal,” the data is sampled directly with the transmit data