5-8
W A N s u i t e 5 1 6 0 / 5 1 3 0
DTR Alarm
Read-only field that displays the current DTR Alarm status. This register
shows “OK” when no alarms are detected, and shows “ALRMD” when the
unit alarms a loss of DTR.
Reset Timer
This field is the contiguous number of seconds that an alarm parameter must
be clear before the alarm is reset. Applicable values range from 000 through
899. A value of “000” means that the alarm never resets. Press
SELECT
to
change this threshold.
Reset Alarms
This option clears the alarm counts. To reset the alarms, press the
SCROLL
button to bring up the “Yes” option, and then press the
SELECT
button.
Performance Menu
The PERFORMANCE menu displays a history of the network error
parameters that are continuously monitored. This register lets you view the
24-hour performance totals from the unit. Only the 5160’s Network 1
Performance menu is shown below in Figure 5.10 because the parameters are
the same for the WANsuite 5160 Network 1 and Network 2 menus and also
for the Network menu in the WANsuite 5130.
Figure 5.10
Performance Menu Tree
The parameters found on this menu are the same as on the Alarms menu tree,
except for the three additional parameters defined below.
Net 1 24-hour
Perf
(read-only fields)
Rx
ES
SES
LOSS
OOFS
BPVS
CSS
RAS
AISS
UAS
CRCES
BES
LOFC
Net 1
Performance