20 intensities, 1 overview, On 20 – LSC Lighting CLARITY LX Series v.1 User Manual
Page 144

Intensities
Clarity
Operator Manual
Page 134
20 Intensities
20.1 OVERVIEW
Select the Programmer’s “Intensities” tab by touching More… then Intensities. The screen
displays the intensity channel of every patched fixture represented by two separate vertical
bars. The left bar shows the programmer level (if any) and the right bar shows the output
level. The numbers below each channel are the fixture “unit numbers” as set in the patch.
The cells are colour coded to indicate the following:
“Inactive”. The channel has no intensity value in an active playback or in a live
programmer.
“Active Playback”. The channel has an intensity value in an active playback.
“Main Playback”. The channel has an intensity value in the main (selected) playback and
the playback is active.
“Programmer - changed”. The channel has an intensity value in a live Programmer.
“Programmer - unchanged”. A cue containing the channel is being edited live and the
channel value has not been changed by the programmer.
Touch the Legend button to display the colour code.
Select channels by clicking on them. A range of channels can be selected by touching and
dragging on the unit numbers. The intensity level of the selected fixtures can be varied by
clicking and dragging on the bar area.
When editing blind you can see at a glance the difference between the on stage values on the
right and the blind programmer levels on the left.