3.5.2.2 Tools Required

The following tool is required to accomplish the task of this section:

Tool

Description

Driver, Nut

1/4-inch

3.5.2.3 Installation Procedure

Note: The Nyquist filter PCB is field-replaceable to enable the user to install optional
data rates.

1. Install the Nyquist filter PCB as a daughter card on the modulator or

demodulator PCB as follows:

Type

Part Number

Used with

TX PCB

AS/4124-1

Baseband Modulator PCB (AS/3969)

RX PCB

AS/4124-2

Baseband Demodulator PCB (AS/3970)

a.

Ensure that each filter has three 10-pin connectors for I/O and power.

b. Mount the card on the four standoffs with a 1/4” hex nut on each standoff to

secure the PCB. Tighten each nut using the 1/4” nut driver.

2. Refer to Figure 3-7 for connector locations.

3.5.2.3.1 Nyquist Filter Removal

1. Remove the TX filter (AS/4124-1) or RX filter (AS/4124-2) as follows:

a.

Open the modem front door and turn off the power.

b. Remove the modulator or demodulator PCB from the modem and place on a

static-free work area.

c.

Remove the four 1/4” hex nuts that secure the filter card (AS/4124-X) using
the 1/4” nut driver.

Note: Do not remove the screws and standoffs from the modulator or
demodulator. Remove the four hex nuts only.

2. Carefully unplug the filter card from the modulator or demodulator connectors.