beautypg.com

Comtech EF Data SDM-9000 User Manual

Page 236

background image

Remote Control Operation

SDM-9000 Satellite Modem

B–18

Rev. 4

Demodulato
r Rate
Status

Command:
Response:

>add/DR_nnnn_mmmm.mmm'cr''lf']

Where:

nnnnn = One of the following decoder rates:

1/2 (QPSK 1/2)
3/4 (QPSK 3/4)
7/8 (QPSK 7/8)
16Q34 (16QAM 3/4)
16Q78 (16QAM 7/8)
8P23 (8PSK 2/3)
8P56 (8PSK 5/6)
N/A (Not Assigned)

mmmmm.mmm = Data rate in kHz.

Receive
Signal Level
Status

Command:
Response:

>add/RSL_xsnndBm'cr''lf']

Where:

x = < or > (data modifier to indicate that the receive
signal level is less than or greater than the returned
value).

s = + or - (receive signal level sign, plus or minus).

nn = 0 to 99 (receive signal level magnitude).

Notes:

1. The 'x' (< or >) parameter is only returned if the

level has exceeded the computational resolution of
the system.

2. 'No Data' is returned if the level cannot be

calculated.

3. 'Sampling' is returned if not enough data is currently

available to calculate the level.

Interface
Buffer Fill
Status

Command:
Response:

>add/IBFS_nn%'cr''lf']

Where: nn = 1 to 99 (relative to buffer depth).

Current
Sweep
Value

Command:
Response:

>add/CSV_snnnnn'cr'
CD_xxx'cr''lf']

Where:

s = + or - (sweep offset from center).
nnnnn = 0 to 60000.
xxx = OK or FLT (decoder lock status OK or FAULT).

This command returns the current sweep value and the
decoder lock status.