beautypg.com

Comtech EF Data SDM-9000 User Manual

Page 182

background image

Maintenance

SDM-9000 Satellite Modem

6–24

Rev. 4

RX 2047 LOCK

RX 2047 lock alarm.

Indicates the RX 2047 data test pattern is not being received by
the decoder. This probably indicates the transmitter is not set
correctly.

BUFFER FULL

Buffer full alarm.

Indicates the buffer is less than 10% or greater than 90% full.

PROGRAMMING

Receive interface programming fault.

Indicates the RX interface module has failed to program a current
configuration parameter. If this fault occurs, contact
EFData Customer Support for assistance.

CONFIGURATION

Receive interface configuration fault.

Indicates the RX interface module does not support a
programmed configuration parameter. This fault typically occurs
when the programmed configuration does not match the module
hardware. Ensure the programming of the RX interface hardware
matches the configuration parameters. Also, verify all jumpers
have been set correctly for currently programmed configuration
parameters.