beautypg.com

B.5 stored faults – Comtech EF Data SDM-9000 User Manual

Page 237

background image

SDM-9000 Satellite Modem

Remote Control Operation

Rev. 4

B–19

B.5 Stored Faults

Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “NO Fault” will be returned instead of the normal
time/date status information.

The following symbols are commonly used to define the stored faults status commands:

#

Fault number (0 to 9). “0” is the first fault stored.

hh

Hours in 24-hr. format.

mm

Minutes.

ss

Seconds.

MM

Month.

DD

Day.

YY

Year.

Modulator
Stored
Faults

Command:
Response:

>add/MSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCA_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SCT_xxx'cr'
EXT_xxx'cr'
PROG_xxx'cr'
CONF_xxx'cr''lf']

Module
IF Synthesizer
Data Clock Activity
Data Clock Synthesizer
I Channel
Q Channel
AGC Level
Internal SCT Synthesizer
External Reference Activity
Programming
Configuration

Demodulato
r Stored
Faults

Command:
Response:

>add/DSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
RCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr'
PROG_xxx'cr'
CONF_xxx'cr''lf']

Demod Module
Carrier Detect
IF Synthesizer Lock
Receive Clock Synthesizer
I Channel
Q Channel
Descrambler
BER Threshold
Programming
Configuration

Interface
Transmit
Side Stored
Faults

Command:
Response:

>add/ITSF_# hh:mm:ss MM/DD/YY'cr'
TXD_xxx'cr'
PLL_xxx'cr'
CLK_xxx'cr'
PROG_xxx'cr'
CONF_xxx'cr''lf']

Transmit Data/AIS
Transmit Synthesizer PLL Lock
Selected Transmit Clock Activity
Programming
Configuration