SDM-9000 Satellite Modem

Remote Control Operation

Rev. 4

B–17

Interface
Read Error
Status

Command:
Response:

>add/IRES_tttt_xn.nE-ee'cr''lf']

Where:

tttt = FRM (FRAME) or 2047 (indicates type of error
being read).

x = < or > (data modifier to indicate that the error rate is
less than or greater than the returned value).

m.m = 1.0 to 9.9 (error rate mantissa).

ee = 1 to 99 (error rate exponent).

This command returns frame or 2047 error rate. The 'IRE_'
configuration command is used to select reading of frame
or 2047 errors.

Notes:

1. The 'x' (< or >) parameter is only returned if the

error rate has exceeded the computational
resolution of the system.

2. 'No Data' is returned if the error rate cannot be

calculated.

3. 'Sampling' is returned if not enough data is currently

available to calculate the error rate.

E

b

/N

0

Status

Command:
Response:

>add/EBN0_xnn.ndB'cr''lf']

Where:

x = < or > (data modifier to indicate that the E

b

/N

0

is

less than or greater than the returned value).

nn.n = 1.0 to 99.9 (E

b

/N

0

value).

Notes:

1. The 'x' (< or >) parameter is only returned if the

E

b

/N

0

has exceeded the computational resolution of

the system.

2. 'No Data' is returned if the E

b

/N

0

cannot be

calculated.

3. 'Sampling' is returned if not enough data is currently

available to calculate the E

b

/N

0

.

Modulator
Rate Status

Command:
Response:

>add/MR_nnnnn_mmmmm.mmm'cr''lf'
]

Where:

nnnnn = One of the following coder rates:

1/2 (QPSK 1/2)
3/4 (QPSK 3/4)
7/8 (QPSK 7/8)
16Q34 (16QAM 3/4)
16Q78 (16QAM 7/8)
8P23 (8PSK 2/3)
8P56 (8PSK 5/6)
N/A (Not Assigned)

mmmmm.mmm = Data rate in kHz.