Comtech EF Data SDM-9000 User Manual
Page 153
SDM-9000 Satellite Modem
Theory of Operation
Rev.4
5–25
The buffer clock source selection must fall within the following parameters:
G.703 Interface
TX Terrestrial
No restrictions.
RX Satellite
No restrictions.
External Clock
Must be in the range from 1.544 to 20 MHz, in 8 kHz steps, or at the RX
terrestrial data rate.
Internal Clock
No restrictions.
ECL Interface
TX Terrestrial
TX and RX terrestrial clocks (data rates) must be divisible by 8 kHz, or the
TX data rate must be the same as the RX data rate.
RX Satellite
No restrictions.
External Clock
The external clock must be in the range from 1.544 to 20 MHz, in 8 kHz
steps, and the RX (data rate) clock must be divisible by 8 kHz.
Additionally, the external clock may be at the RX (data) clock rate.
Internal Clock
Refer to “TX Terrestrial.” This clock is at the same frequency as the TX
terrestrial clock.
MIL-STD-188 Interface
TX Terrestrial
TX and RX terrestrial clocks (data rates) must be divisible by 8 kHz, or the
transmit data rate must be the same as the receive data rate.
RX Satellite
No restrictions.
External Clock
The external clock must be in the range from 1.544 to 20 MHz, in 8 kHz
steps, and the RX (data rate) clock must be divisible by 8 kHz.
Additionally, the external clock may be at the RX (data) clock rate.
Internal Clock
Refer to “TX Terrestrial.” This clock is at the same frequency as the TX
terrestrial clock.
Note: G.703 interfaces have the option of HDB3 or B3ZS line coding data to the
terrestrial interface. This selection shall be made by the user.