beautypg.com

Comtech EF Data SDM-9000 User Manual

Page 226

background image

Remote Control Operation

SDM-9000 Satellite Modem

B–8

Rev. 4

Interface
Substitute
Pattern
(Transmit
2047
Pattern)

Command:
Response:

Status:
Response:

>add/ISP_xxx'cr''lf']

>add/ISP_xxx'cr''lf']

Where: xxx = ON or OFF.

Interface
Read Error
Select
(Receive
2047
Pattern)

Command:
Response:

Status:
Response:

>add/IRE_xxx'cr''lf']

>add/IRE_xxx'cr''lf']

Where: xxx = ON or OFF.

Interface
Service
Channel
Level

Command:
Response:

Status:
Response:

>add/ISCL_xxx_nnn'cr''lf']

>add/ISCL_xxx_nnn'cr''lf']

Where:

xxx = TX1, TX2, RX1, or RX2 (service channel designator).
nnn = -20 to +10, in steps of 1 (service channel level in
dBm).

Interface
Transmit
Overhead
Type

Command:
Response:

Status:
Response:

>add/ITOT_xxxx'cr''lf']

>add/ITOT_xxxx'cr''lf']

Where: xxxx = NONE or IDR.

Note: If the ESC Option is not installed, only 'NONE' will be
allowed.

Interface
Receive
Overhead
Type

Command:
Response:

Status:
Response:

>add/IROT_xxxx'cr''lf']

>add/IROT_xxxx'cr''lf']

Where: xxxx = NONE or IDR.

Note: If the ESC Option is not installed, only 'NONE' will be
allowed.

Transmit
Data Phase

Command:
Response:

Status:
Response:

>add/TDP_xxxx'cr''lf']

>add/TDP_xxxx'cr''lf']

Where: xxxx = NRM (normal data phasing) or INV (inverted
data phasing).

Receive
Data Phase

Command:
Response:

Status:
Response:

>add/RDP_xxxx'cr''lf']

>add/RDP_xxxx'cr''lf']

Where: xxxx = NRM (normal data phasing) or INV (inverted
data phasing).

IDR
Backward
Alarm
Enable

Command:
Response:

Status:
Response:

>add/BW_xxx_nnn'cr''lf']

>add/BW_xxx_nnn'cr''lf']

Where:

xxx = TX1, TX2, TX3, TX4, RX1, RX2, RX3, or RX4
(backward alarm designator).

nnn = ON or OFF.

Scrambler
Type

Command:
Response:

Status:
Response:

>add/SCRT_xxxx'cr''lf']

>add/SCRT_xxxx'cr''lf']

Where: xxxx = V.35, EFD, or IDR.

Descramble
r Type

Command:
Response:

Status:
Response:

>add/DSCT_xxxx'cr''lf']

>add/DSCT_xxxx'cr''lf']

Where: xxxx = V.35, EFD, or IDR.