2.4.10 Alarms (J10)

The alarms connector is used to provide three Form C contact closures for alarm
reporting, as follows:

Alarm 1 = Not used

Alarm 2 = TX

Alarm 3 = RX

The two Form C summary fault contacts currently used are:

Transmit alarm (Alarm 2)

Receive alarm (Alarm 3)

Refer to Chapter 4 for a discussion of alarms monitored. To obtain a system summary
alarm, connect all the Form C contacts in parallel.

The alarms connection is a 9-pin female D connector located on the rear panel of the
modem. Screw locks are provided for mechanical security on the mating connector.

Signal Function

Name

Pin #

Alarm 1 is OK

NO

1

Common

COM

2

Alarm 1 is faulted

NC

3

Alarm 2 is OK

NO

4

Common

COM

5

Alarm 2 is faulted

NC

6

Alarm 3 is OK

NO

7

Common

COM

8

Alarm 3 is faulted

NC

9

Note: A connection between the common (COM) and normally open (NO) contacts