beautypg.com

17 level meters, 18 faders, 19 mute – Cadac R-Type User Manual

Page 85: 20 vca, 21 insert, 22 mtx pre, 23 listen, 24 pre-ins monitor select, 25 pre/post fader monitor select, 26 mono/stereo

background image

Outputs and Matrix 8251

9-7

Revision R2005-2

R-Type

<1414: /HYHO#PHWHUV

These post-fader level meters indicate the OUTPUT signal level. The meters are
affected by the MUTE switch.

<1414; )DGHUV

These are 60mm conductive plastic faders which are used to adjust the level of the A
and B OUTPUTS.

<1414< 087(

Press to MUTE each OUTPUT.

<14153 9&$

Press to enable each OUTPUT to be connected to the DC and MG assignments in
the fader below.

<14154 ,16HUW

Press to connect the pre-fader send/return insert jacks into the signal path.

<14155 07;#35(

Press to enable the OUTPUT to be routed to the MATRIX from pre-fader.

<14156 /,67(1

Press to monitor each output A or B.

<14157 3UH0,16#PRQLWRU#VHOHFW

Press to select the monitored output to be Pre-insert.

<14158 3UH23RVW#IDGHU#PRQLWRU#VHOHFW

Press to select the monitored output to be Pre/Post fader.

<14159 0212267(5(2

Press to select MONO for independent operation of A and B buttons, or STEREO to
have them act as a pair.