3 list of error messages, Perational, Failures – Avery Dennison ALS 306 User Manual
Page 54: Tatus, Messages, List of error messages
55
6.1 S
TATUS
MESSAGES
ALS
306
309
GB
6.1.3
List of error messages
Status
Status text
Cause
Action to take
5000
Bus device
– Device at I
2
C Bus cannot be
contacted.
– In most cases, this message appears
as the first in a series of two or three
messages which narrow down the
error more precisely.
£
Delete the message by pressing the
-key.
£
Switch the machine off, wait 30
seconds and switch it back on.
£
If the error message
appears
repeatedly, call in a servicing
technician.
5001
No gap found
– Material end, if no outer diameter
(OD) control is activated.
– The maximum limit for missing labels
was exceeded (
LABEL SETUP >
Miss. label tol.
).
– The machine is not correctly set for
the type of label (
MACHINE SETUP >
Light sens. type
).
– Label length is not correctly set
(
LABEL SETUP > Label pitch
).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is
incorrectly positioned.
– Photoelectric label sensor is not
connected correctly.
– Photoelectric label sensor is
defective.
– Rotary encoder is not adjusted
correctly.
£
Check the points listed above and
correct if necessary.
£
Press the
key to confirm the
error message.
5002
Material end
– Material end (if the internal OD-
control is connected and activated).
– Internal OD-control is not connected,
but activated
£
Insert new label roll.
£
Deactivate the internal OD-control:
MACHINE STATUS > Material end err
=
„Off“.
5026
MotorProtect CPU
– Dust filter liner exhausted. This leads
to overheating the machine.
– There are some more possible
causes, which require a qualified
service technician to cure.
£
Renew the dust filter liner. Let the
machine cool down
£
Switch the machine off, wait 30
seconds and switch it back on.
£
If none of the above listed actions is
successful, search for technical
assistance.
[59]
List of error messages