beautypg.com

3 positioning the label sensor, 4 setting the dancer arm restoring force – Avery Dennison ALS 306 User Manual

Page 41

background image

42

3

B

EFORE

OPERATION

3.3 M

ECHANICAL

SETTINGS

ALS

306
309

GB

3.3.3

Positioning the label sensor

£

Release the thumb screw.

£

Position the sensor along the axle in such a way as
to allow it to register the spaces between the labels.

The LED [45A] lights up when the sensor is
positioned over a label.

3.3.4

Setting the dancer arm
restoring force

The unwinder dancer arm is preset in a way, that a wide
range of label materials can be processed whithout ha-
ving to change the dancer arms restoring force.

Even so, very narrow label material can under certain
circumstances tear off or expand in a way which results
in poor labelling precision. In those cases, the restoring
force must be decreased.

£

Loosen the lock-ring [47B]. To do so, hold the
adjustment ring [47A] and turn the lock-ring
opposite the direction indicated by the pictured
arrow.

£

Turn the adjustment ring [47A] in arrow direction
[47 arrow] to increase the restoring force.
Turn the adjustment ring [47A] against arrow
direction [47 arrow] to decrease the restoring force.

£

Retighten the lock ring against the adjustment ring.

A service technician can restore the factory set-
ting, see service manual chap. 6.2.3 section
„Adjusting restoring force of dancer arm“.

[45] Label sensor from Wenglor, model OPT242-P800

B

A

[46] Restoring spring (A) at the unwinder dancer arm.

[47] A Adjustment ring

B Lock-ring

A

A

B