3 operating modes, 1 dispensing mode, Stopping / continuing the dispensing mode – Avery Dennison ALS 306 User Manual
Page 23: Changing the counter reading, Starting the unit in configuration mode, Counting labels backwards, 2 . 3 o p e r a t i n g m o d e s
![background image](https://www.manualsdir.com/files/772981/content/doc023.png)
24
2.3 O
PERATING
MODES
ALS
306
309
GB
2.3.1
Dispensing mode
This is the operating mode of the unit when switched
on. You can carry out the functions listed in the sections
below.
If text such as ‘Prof 5 xxxxxxxx’ is displayed
instead of ‘ONLINE’:
– The ‘xxxxxxxx’ product profile (memory
location 5) is activated.
– For more information, see the ‘Using product
profiles’ section.
Stopping /Continuing the dispensing
mode
Stopping the dispensing mode:
£
Press the
button.
– Display:
Continuing the dispensing mode:
£
Press the
button.
Changing the counter reading
£
Set the counter reading using the
MACHINE SETUP >
Dispense counter
function.
Starting the unit in configuration mode
To start the unit in configuration mode:
£
Set
MACHINE SETUP > Turn-on mode
to ‘Offline’.
Counting labels backwards
To count dispensed labels backwards from a starting
value to zero:
£
Set
LABEL SETUP > Stop count. mode
to ‘Enabled’.
£
Use the
LABEL SETUP > Label stop quan.
function to
define the starting value.
ONLINE
Stopped:
xxx
[18] Control panel in dispensing mode (292 labels dispensed)
A Explanation of buttons in dispensing mode
+
+
–
–
ON
STATUS
Online
292
Labels
A
2.3
OPERATING MODES