2 configuration and monitoring, 1 function menu settings, Label pitch – Avery Dennison ALS 306 User Manual
Page 44: Label stop position, Label pitch label stop position, Peration, Onfiguration, Monitoring, Function menu settings
45
4.2 C
ONFIGURATION
AND
MONITORING
ALS
306
309
GB
4.2.1
Function menu settings
Label pitch
£
Switch to configuration mode
Calibrating the label pitch automatically:
£
Hold down the button
for a while (longer than
two seconds).
Or: Enter the label pitch manually:
£
Measure the label pitch [49C].
£
Call the
LABEL SETUP > Label pitch
function.
£
Enter the measured value in millimetres.
Label stop position
Prerequisites:
– The label length must be specified.
The next label to be dispensed waits in the label stop
position. Here it is useful if the label protrudes over the
dispensing edge a little [50].
ALS 30x labellers are pre-configured for use
with the supplied label sensor. If this sensor is
employed, the label stop position setting will
only require minimal correction.
Correcting the default setting:
£
Call the
LABEL SETUP > Lab. stop offset
function.
£
Increase the value to increase the overhang or
lower the value to reduce the overhang.
The value ‘0’ will cause the label to stop with its front
edge directly under the label sensor.
The front edge of the next label to be dispensed should
be flush with the dispensing edge:
£
Enter the distance [50A] between the label sensor
and the dispensing edge.
The front edge of the label to be dispensed should
overhang:
£
Add the length of the overhang to the distance
between the label sensor and the dispensing edge.
[49] A Label web
B Label
C Label pitch
A
B
C
[50] Label stop position (A)
A