4.2.1

Function menu settings

Label pitch

£

Switch to configuration mode

Calibrating the label pitch automatically:

£

Hold down the button

for a while (longer than

two seconds).

Or: Enter the label pitch manually:

£

Measure the label pitch [49C].

£

Call the

LABEL SETUP > Label pitch

function.

£

Enter the measured value in millimetres.

Label stop position

Prerequisites:

– The label length must be specified.

The next label to be dispensed waits in the label stop
position. Here it is useful if the label protrudes over the
dispensing edge a little [50].

ALS 30x labellers are pre-configured for use
with the supplied label sensor. If this sensor is
employed, the label stop position setting will
only require minimal correction.

Correcting the default setting:

£

Call the

LABEL SETUP > Lab. stop offset

function.

£

Increase the value to increase the overhang or
lower the value to reduce the overhang.

The value ‘0’ will cause the label to stop with its front
edge directly under the label sensor.

The front edge of the next label to be dispensed should
be flush with the dispensing edge:

£

Enter the distance [50A] between the label sensor
and the dispensing edge.

The front edge of the label to be dispensed should
overhang:

£

Add the length of the overhang to the distance
between the label sensor and the dispensing edge.

[49] A Label web

B Label
C Label pitch

A

B

C

[50] Label stop position (A)

A

4.2

CONFIGURATION AND MONITORING