beautypg.com

Avery Dennison Sierra Sport2 9460 RCL Commands Programmer Manual User Manual

Page 46

background image

3-16 Command Reference

data_attrib

The field attributes.

0

The field is a line, graphic, or a variable text or

bar code that neither increments nor

decrements.

1*

The field data never changes (text).

2*#

Incrementing field (text or bar code).

3*

Decrementing field (text or bar code).

* These fields require you to enter something in the

fixed_data field.
# Do Not use an MSI bar code with an incrementing

text field. This combination may cause the check

digit on the MSI bar code to be incorrect.

fixed_data

If the field never changes, enter up to 200 bytes of

data in this field. Or, if it is an incrementing or

decrementing field, enter the starting number in this

field. Otherwise, leave it blank (but include the split

vertical bar).

If you enter something in this field, when you print the

format with the ^P command, leave the part (for data)

corresponding to this field blank. Be sure to include

the split vertical bar to delimit the field.

Except for the single incrementing or decrementing

field per format, you cannot use this field for a bar

code.

To create a new line, use carriage return and/or line

feed.

Example

^R¦1¦R¦50¦50¦10¦35¦0¦0¦0¦10¦4¦4¦0¦0¦¦^

This command defines a field that is at point (50,50) and is 10 dots
wide and 35 dots long. This field is fixed, left justified, and not rotated.
Also, this field uses font 10 and is 4 times as wide and high than
normal.

This manual is related to the following products: