Getting Started 1-5

Example

In the following data stream, ^R¦$¦DR¦^ deletes all current fields and
formats, and all the other commands define the fields on the appliance
label.

^R¦$¦DR¦^ DELETE CURRENT FIELDS

^R¦1¦R¦20¦10¦354¦25¦0¦0¦0¦8¦1¦1¦0¦0¦¦^ PRICE FIELD

^R¦2¦R¦20¦85¦340¦25¦0¦0¦0¦8¦1¦1¦0¦0¦¦^ DESC FIELD 1

^R¦3¦R¦20¦105¦340¦25¦0¦0¦0¦8¦1¦1¦0¦0¦¦^ DESC FIELD 2

^R¦4¦R¦20¦130¦340¦60¦0¦0¦0¦a¦3¦0¦48¦0¦¦^ UPCA

^R¦5¦R¦345¦142¦30¦25¦0¦0¦0¦8¦1¦1¦0¦0¦¦^ "A" IN BOX

^R¦6¦R¦10¦200¦300¦25¦0¦0¦0¦8¦1¦1¦0¦0¦¦^ UNDER UPCA

^R¦7¦R¦330¦130¦50¦50¦0¦0¦0¦A¦3¦0¦0¦0¦¦^ BOX

Command Summary

The ^R command deletes or defines a field. To define a field, specify
the following items:

field identifier

position of the field

length and width of the field

field type

attributes, such as rotation, justification, and multipliers.

Due to space limitations in this manual, this

command summary appears on two pages. In a

data stream, this command must appear on one

line.