3 requirements, 1 environmental requirements, Table 2-2 – Artesyn MVME4100ET Single Board Computer Installation and Use (June 2014) User Manual
Page 27: Mvme4100et specifications, Hardware preparation and installation
Hardware Preparation and Installation
MVME4100ET Single Board Computer Installation and Use (6806800K76F)
27
2.3
Requirements
Make sure that the board, when operated in your particular system configuration, meets the
requirements specified in the next sections.
2.3.1
Environmental Requirements
The following table lists the currently available specifications for the environmental
characteristics of the MVME4100ET. A complete functional description of the MVME4100ET
base board is available in
Chapter 4, Functional Description
.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Table 2-2 MVME4100ET Specifications
Characteristics
Operating
Cooling Method
Force Air
Operating Temperature
-40C to +71C
Storage Temperature
-50C to +100C
Temperature Transition Time
Operational temperature transition rate
0.5c/minute
Vibration
Swept sine: 1.0 g from 5.0 to 200 Hz
Sweep rate: 0.25 octaves/minute
Humidity
Designed to operate up to 100% relative
humidity, Non condensing
The RTC field removable battery should be removed, if MVME4100ET has to be stored beyond
its operational temperature range.