Slew:both Page 73: Tran:twid
Page 73: Tran:twid

69
This command sets the slew time for positive going transitions. MINimum sets the slew to the fastest
possible time. MAXimum sets the slew to the slowest time.
Command Syntax
SLEW
SLEW:POS
Parameters
slew time, refer to model specifications | MIN | MAX
Unit
ms
Query Syntax
SLEW?
SLEW? MIN
SLEW? MAX
SLEW:POS?
SLEW:POS? MIN
SLEW:POS? MAX
Returned Parameters
SLEW:BOTH
This command sets the slew time for all programmed changes. This command programs both positive
and negative going slew time.
Command Syntax
SLEW:BOTH
Parameters
Refer to model specifications | MIN | MAX
Unit
ms
SLEW:NEG
This command sets the slew time for negative going transitions. MINimum sets the slew to the fastest
possible time. MAXimum sets the slew to the slowest time.
Command Syntax
SLEW:NEG
Parameters
Refer to model specifications | MIN | MAX
Unit
ms
Query Syntax
SLEW:NEG?
SLEW:NEG?
MIN SLEW:NEG? MAX
Returned Parameters
TLEV
This command specifies the value for the TRANsient input.
Command Syntax
TLEV
Parameters
Refer individual model specification | MIN | MAX.
Query Syntax
TLEV?
TLEV?
MIN TLEV? MAX
Returned Parameters
TRAN:TWID
This command sets the pulse width of the transients when the generator is in PULSe mode.
Command Syntax
TRAN:TWID
Parameters
Refer to model’s specification | MAX | MIN
Unit
ms
Query Syntax
TRAN:TWID?
Returned Parameters
pulse
width
value in ms