49
Returned Parameters
Four
fields:
assigned flag of DHCP, same as SYST:NET:DHCP?
address> IP address, same as SYST:NET:ADDR? string> identification string, same as *IDN? SYSTem:NET:SUBNet The command sets or queries the device subnet mask. Command Syntax SYSTem:NET:SUBNet Parameters Query Syntax SYSTem:NET:SUBNet? Returned Parameters SYSTem:RANGe This command queries the range number for all four operational modes. Query Syntax SYSTem:RANGe? Returned Parameters nn1 = range number of constant voltage nn2 = range number of constant current nn3 = range number of constant resistance nn4 = range number of constant power SYSTem:SERial? This command queries the serial number of the main control board. Query Syntax SYSTem:SERial? Parameters None Returned Parameters SN:000B87 = Fixed string XXXXXX = serial number of main control board SYSTem:SHORT:STATus? This command queries the serial number of the main control board. Query Syntax SYSTem:SHORt:STATus? Parameters 0 = OFF 1 = ON Returned Parameters SYSTem:VERSion? This query returns the firmware version. The value is of the form FVX.XX, where X.XX is the revision Query Syntax SYSTem:ERSion? Parameters None Returned Parameters
number.