beautypg.com

AMETEK PLA-PLW Programming Manual User Manual

Page 12

background image

10

Position Name

0 OPC

Operation Complete. The electronic load has completed all pending operations.
Programming *OPC causes this bit to be set when the electronic load completes all
pending operations

1 N.A.

2 QYE

Query Error. The output queue was read when no data was present or the data in
the queue was lost.

3 DDE

Device Dependent Error. Memory was lost, or self-test failed.

4 EXE

Execution Error. A command parameter was outside the legal range or inconsistent
with the electronic load’s operation, or the command could not be executed due to
some operating condition.

5 CME

Command Error. A syntax or semantic error has occurred or the electronic load
received a < GET > within a program message.

6 N.A.

7 PON

Power On. The electronic load has been turned on or off since the last time this
register was read. This bit is always set when the electronic load is turned on.

Query Syntax

*ESR?

Returned Parameters

Value: 0 to 255

Suffix

None

*IDN?

System Identification. This command queries the electronic load to identify itself.

Query Syntax

*IDN?

Returned Parameters

form consisting of five fields separated by commas. The content
of each string is:

Field

Information

----------------------------------------------------------------------------

AMREL Manufacturer

EL

Model

name

x

0

xxxx.xxx

CF92.1CT

FVxx.xx

Revision level of primary interface firmware

*OPC

Operation Complete Event Bit Command. This command causes Bit 0 of the Standard Event
Status Event register to be set when the electronic load has completed all pending operations. (See
*ESR? for the bit configuration of this register.) Pending operations are complete when:

Ϯ All

previous commands have been executed.

Ϯ Any

change in the input level caused by previous commands has been completed.

(Effects of slew time have been accounted for.)

Ϯ No pending trigger level operations are set for the single electronic load or for any

channel of the multiple electronic load.

*OPC does not prevent processing of subsequent commands but Bit 0 will not be set until all pending
operations are complete

Command Syntax

*OPC

Parameters

None

*OPC?