incoming triggers while the input is shut down and will respond to the trigger as soon as the protection
fault is cleared.
The :PROTection:DELay command specifies the time that the input power may equal or exceed
POWer:PROTection[:LEVel] or equal or fall below the POWer:PROTection:UNDer[:LEVel] before the
soft circuit breaker is actuated. The PROTection:STATe command enables or disables the soft circuit
breaker function.
Note : If the soft circuit breaker function causes the input to shut down, it will not affect INP[STATe]. If
INP:STAT is programmed ON, it will remain so even after the POWer:PROT has turned the electronic
load off.
Command Syntax
POWer:PROTection
Set immediate overpower
protection
limit.
POWer:PROTection:OVER
protection
limit.
POWer:PROTection:DELay
above :LEVel before input is turned off.
POWer:PROTection:OVER:DELay
Set time that power may be at or
above :LEVel before input is turned off.
POWer:PROTection:UND:DELay
above :LEVel before input is turned off.
POWer:PROTection:STATe OFF|0
Disable over protection function.
POWer:PROTection:STATe
ON|1
Enable over protection function.
POWer:PROTection:UNDer
POWer:PROTection:UND:STAT OF|0
Disable under protection function.
POWer:PROTection:UND:STAT ON|1
Enable under protection function.
Parameters
Refer individual model specification for | MIN | MAX
Query Syntax
POWer:PROTection?
POWer:PROTection?
MIN
POWer:PROTection?
MAX
POWer:PROTection:OVER?
POWer:PROTection:OVER? MIN
POWer:PROTection:OVER? MAX
POWer:PROTection:DELay?
POWer:PROTection:DELay? MIN
POWer:PROTectionDELay? MAX
POWer:PROTection:DELay?
POWer:PROTection:OVER:DELay? MIN
POWer:PROTection:OVER:DELay?MAX
POWer:PROTection:UNDer:DELay?
POWer:PROTection:UNDer:DELay? MIN
POWer:PROTection:UNDer:DELay? MAX
POWer:PROTection:STATe?
POWer:PROTection:UNDer?
POWer:PROTection:UNDer?
MIN
POWer:PROTection:UNDer?
MAX
POWer:PROTection:UNDer:STATe?
[SOURce:]POWer:SLEW:BOTH
This command sets the slew time for all programmed changes in the input power level of the
electronic load. This command programs both positive and negative going slew time. Although any
slew time value may be entered, the electronic load selects a slew time that is closest to the