Page 21

background image

19

incoming triggers while the input is shut down and will respond to the trigger as soon as the protection
fault is cleared.

The :PROTection:DELay command specifies the time that the input current may equal or exceed
CURRent:PROTection[:LEVel] or equal or fall below the CURRent:PROTection:UNDer[:LEVel] before
the soft circuit breaker is actuated. The PROTection:STATe command enables or disables the soft
circuit breaker function.

Note : If the soft circuit breaker function causes the input to shut down, it will not affect INP[STATe]. If
INP:STAT is programmed ON, it will remain so even after the CURR:PROT has turned the electronic
load off.

Command Syntax
CURRent:PROTection

Set immediate over-current

protection

limit.

CURRent:PROTection:OVER

Set immediate over-current

protection

limit.

CURRent:PROTection:DELay

Set time that current may be at or above
limit before input is turned off.

CURRent:PROTection:OVER:DELay

Set time that current may be at or above
limit before input is turned off.

CURRent:PROTection:UNDer:DELay

Set time that current may be at or below
limit before input is turned off.

CURRent:PROTection:STATe OFF|0

Disable over protection function.

CURRent:PROTection:STATe ON|1

Enable over protection function.

CURRent:PROTection:UNDer

Set immediate under-current protection
limit.

CURRent:PROTection:UNDer:STATe OFF|0

Disable under current protection function.

CURRent:PROTection:UNDer:STATe ON|1

Enable under current protection function.

Parameters

Refer individual model specification for MIN | MAX value.

Query Syntax

CURRent:PROTection?

CURRent:PROTection? MIN CURRent:PROTection? MAX

CURRent:PROTection:OVER?

CURRent:PROTection:OVER? MIN

CURRent:PROTection:OVER? MAX

CURRent:PROTection:DELay?

CURRent:PROTection:DELay? MIN

CURRent:PROTection:DELay? MAX

CURRent:PROTection:OVER:DELay?

CURRent:PROTection:OVER:DELay? MIN

CURRent:PROTection:OVER:DELay?MAX

CURRent:PROTection:UNDer:DELay?

CURRent:PROTection:UNDer:DELay? MIN

CURRent:PROTection:UNDer:DELay?MAX

CURRent:PROTection:STATe?

CURRent:PROTection:UNDer?

CURRent:PROTection:UNDer?

MIN

CURRent:PROTection:UNDer?

MAX

CURRent:PROTection:UNDer:STATe?

Returned Parameters

Depending on the actual query.

[SOURce:]CURRent:SLEW:BOTH

This command sets the slew time for all programmed changes in the input current level of the
electronic load. This command programs both positive and negative going slew time. Although any