beautypg.com

Tility, Ommands – AMETEK PLA-PLW Programming Manual User Manual

Page 57

background image

53

U

TILITY

C

OMMANDS

UTILity:RANGe

This command selects and queries the range control mode.

Command Syntax

UTILity:RANGe

Parameters

range control mode.

0 : manual mode,

1 : auto mode,

Query Syntax

UTILity:RANGe?

Returned Parameters

integer representing range control mode

UTILity:MEASure:SENSe

This command sets or queries the measurement sense (Local / Remote ).

Note: When input voltage is greater than 30 V, this command will cause an execution error.

Command Syntax

UTILity:MEASure:SENSe

Parameters

0 | 1 | LOCal(0) | REMote(1)

Query Syntax

UTILity:MEASure:SENSe?

Returned Parameters

0=LOCal

1=REMote

UTILity:TR:MODE
UTILity:TRANsient:MODE

This command selects the operating mode of the transient generator as follows.

TRIGger

The transient switch to trigger levels upon receipt of a trigger.

CONTinuous The

transient generator puts out a continuous pulse stream.

TOGGle

The

transient generator toggles between two levels upon receipt of a

trigger.

PULSe

The

transient generator puts out a single pulse upon receipt of a trigger.

Command Syntax

TR:MODe
TRANsient:MODe

Parameters

transient mode

0:TRIGger

1:CONTinuous

2:TOGGle

3:PULSe

4:STEP

5:AUTO

6:ONCE

Query Syntax

TR:MODe?
TRANsient:MODe?

Returned Parameters

integer value representing transient mode