Tility, Ommands – AMETEK PLA-PLW Programming Manual User Manual
Page 57

53
U
TILITY
C
OMMANDS
UTILity:RANGe
This command selects and queries the range control mode.
Command Syntax
UTILity:RANGe
Parameters
range control mode.
0 : manual mode,
1 : auto mode,
Query Syntax
UTILity:RANGe?
Returned Parameters
UTILity:MEASure:SENSe
This command sets or queries the measurement sense (Local / Remote ).
Note: When input voltage is greater than 30 V, this command will cause an execution error.
Command Syntax
UTILity:MEASure:SENSe
Parameters
0 | 1 | LOCal(0) | REMote(1)
Query Syntax
UTILity:MEASure:SENSe?
Returned Parameters
1=REMote
UTILity:TR:MODE
UTILity:TRANsient:MODE
This command selects the operating mode of the transient generator as follows.
TRIGger
The transient switch to trigger levels upon receipt of a trigger.
CONTinuous The
transient generator puts out a continuous pulse stream.
TOGGle
The
transient generator toggles between two levels upon receipt of a
trigger.
PULSe
The
transient generator puts out a single pulse upon receipt of a trigger.
Command Syntax
TR:MODe
TRANsient:MODe
Parameters
0:TRIGger
1:CONTinuous
2:TOGGle
3:PULSe
4:STEP
5:AUTO
6:ONCE
Query Syntax
TR:MODe?
TRANsient:MODe?
Returned Parameters