Ystem, Ommands – AMETEK PLA-PLW Programming Manual User Manual
Page 48

44
S
YSTEM
C
OMMANDS
System commands control the system-level functions of the electronic load that are not
directly related to input control or measurement functions.
SYSTem:CHANnel:VERSion?
This query returns the firmware version of analog control
Query Syntax
SYSTem:CHANnel:VERSion?
Parameters
None
Returned Parameters
YY = year
MM
=
month
DD = day
SYSTem:COMMand:SYNTax
This command sets or queries the syntax mode state
Command Syntax
SYSTem:COMMand:SYNTax
Parameters
0 = PEL Syntax Mode
1 = PLA/PLW Syntax Mode
Query Syntax
SYSTem:COMMand:SYNTax?
Parameters
None
Returned Parameters
SYSTem:CONSole:BAUD
This command sets or queries the value of baud rate for RS-232 interface.
Command Syntax
SYSTem:CONSole:BAUD
Parameters
Query Syntax
SYSTem:CONSole:BAUD?
Parameters
None
Returned Parameters
Note: Default baud rate is set to 115200.
SYSTem:CONSole:EOS
This command sets or queries the value of the end-of-string (EOS) code for RS-232 interface.
Command Syntax
SYSTem:CONSole:EOS
Parameters
0 = NULL(no EOS)
1 = CR
2 = LF
3 = CR/LF
Query Syntax
SYSTem:CONSol:EOS?
Parameters
None