55

return the presently programmed voltage levels. After a trigger or ABORt,

VOLTage:TRIG? returns the same value as VOLTage? .

VOLTage? MAX, VOLTage? MIN, VOLTage:TRIG? MAX and
VOLTage:TRIG? MIN return the maximum and minimum programmable
LEVel and TLEVel values.

[SOURce:]VOLTage:[TRANsient:]DUTY

This command sets the duty cycle of each of the transients when the generator is in CONTinuous
mode.

Command Syntax

VOLTage:DUTY

VOLTage:TRANsient:DUTY

Parameters

Duty cycle value, 1 - 100

Unit

Percentage

Query Syntax

VOLTage:DUTY?

VOLTage:DUTY? MIN

VOLTage:DUTY? MAX

VOLTage:TRANsient:DUTY?

VOLTage:TRANsient:DUTY? MIN

VOLTage:TRANsient:DUTY? MAX

Returned Parameters

an integer representing duty cycle value

[SOURce:]VOLTage:[TRANsient:]FREQuency

This command sets the frequency of the transients when the generator is in CONTinuous mode.

Command Syntax

VOLTage:FREQuency

VOLTage:TRANsient:FREQuency

Parameters

Frequency value, refer to model specifications | MIN | MAX

Unit

Hertz

Query Syntax

VOLTage:FREQuency?

VOLTage: FREQuency? MIN

VOLTage:FREQuency? MAX

VOLTage:TRANsient:FREQuency?

VOLTage:TRANsient:FREQuency? MIN

VOLTage:TRANsient:FREQuency? MAX

Returned Parameters

frequency value in Hz

[SOURce:]VOLTage:PROTection[:LEVel]
[SOURce:]VOLTage:PROTection:OVER[:LEVel]
[SOURce:]VOLTage:PROTection:DELay
[SOURce:]VOLTage:PROTection:OVER:DELay
[SOURce:]VOLTage:PROTection:UNDer:DELay
[SOURce:]VOLTage:PROTection:STATe
[SOURce:]VOLTage:PROTection:UNDer[:LEVel]
[SOURce:]VOLTage:PROTection:UNDer:STATe

Channel-Specific Voltage Limiting Command/Query. This command sets the over-voltage
protection limit or the under-voltage protect limit to the input voltage that the electronic load will sink.
When the input voltage reaches the protection limit for the specified delay period, the input of the
electronic load is shut off and draws no voltage.

The INPut:PROTection:CLEar command (or front panel key) re-enables the input voltage. The trigger
activated voltage functions (VOLTage[:LEV]:TRIG and VOLTage:TLEV) automatically keep track of