Loop Start Signaling

November 2009

310

event = 1 in the IISDN_ROBBED_BIT_DATA structure. This

message is sent after the fixed pause timer expires. When the timer

expires, the host receives an L3L4mSEIZE_COMP message if send_

seize_comp_event = 1 in the IISDN_ROBBED_BIT_DATA structure.

FXS ground start supports transmitting digits other than dial pulse

digits. If called_party_digits = 0 in the L4L3mCALL_REQUEST that

started the call, the module waits in outdialing state indefinitely.

During that time, another device connected to the Brooktrout

module over the TDM bus (such as a digital tone generator) is used

to outpulse digits to the network.

After the digits are transmitted, the module waits for an answer

timer to expire (if timed_answer_supervision = 1). When the timer

expires, the host receives an L3L4mCONNECT indicating the call is

connected.

Figure 44

shows how the module makes an outgoing call over an

FXS ground start trunk.

Call Teardown Processing

In this mode, an incoming call teardown cannot be detected; the host

must determine when the call is inactive (that is. no data) and

initiate an outgoing call teardown. For an outgoing call teardown,

refer to

Figure 45

.