beautypg.com

Command syntax – Dialogic 6.2 User Manual

Page 128

background image

boardmon

November 2009

128

the state of the signaling bits and alarms. It also counts the errors

(e.g., framing errors, CRC errors, clock slips, BPVs) on each span. It

only works with spans that are configured for robbed-bit signaling

and where telephony connections have been made.

The spans are numbered starting from 1 which is the first interface

on a module.

The btcall.cfg file is the user configuration file. The boardmon

application is found in the bapp.src directory.

Command Syntax

boardmon [-m ] [-s ] [-d] [-v] [-h]

While the program is running you can press a key to reset the error

counters or to quit. When running under Unix, you must press

Enter after pressing the key.

Arguments

-m

Use specified module (default 2)

-s

Use specified span only [1-4] (default all)

-d

Enable program debug mode

-v

Enable Bfv API debug mode

-h

Help

1

Reset error counters for span 1

2

Reset error counters for span 2

3

Reset error counters for span 3

4

Reset error counters for span 4

r or R

Reset error counters for all spans

q or Q

Quit the program