pulseToneDuration

Duration of a backward pulse

signal (Ref. ITU Q.442).

ms

Typically [100 - 200]

Outbound MFC Timers

forwardToneMaxOnTime

Time associated with the outbound

“T1” timer that supervises the

interval between start of a forward

tone and cessation of the forward

tone (Ref. ITU Q.476).

Seconds This is typically in the

range [12-18], but refer

to network

specification.

forwardToneMaxOffTime

Time associated with the outbound

“T2” timer that supervises the

interval when no forward tones are

sent. This interval consists of the

period waiting for the backward

tone to stop, as well as any

additional time needed for the next

forward tone to be known.

Seconds Typically set to > 24

(Q.476), but refer to

network specification.

forwardGroup2MaxOnTime

Not used.

Seconds Not used.

Protocol Control

dnisTimeOutAction

Not used.

Not used.

Protocol State Transition Specification
Each of the following is an array of length 16. Element zero is invalid and elements 1-15 correspond to

R2 MF signals 1-15. These allow the Call Setup Service Pack software to construct the proper state

transition tables for a given trunk.

Forward Channel Signal Definitions

endOfDNIS

Signal end of DNIS pulsing; NOT

defined in some variants.

Table 20

endOfANI_Available

Signal end of ANI identification

when ANI digits are available.

Table 20

InfoNotAvailable

Indicates that ANI information is

restricted. There is usually no need

to distinguish from signal

“aniRequestNotAccepted”.

Table 20

aniCategoryDefault

Default Group 1 category. Used if

category is not specified in a given

call request.

Table 20

Table 19. R2 MFC Inter-register Signaling Parameters (Continued)

Name

Description

Units