Set_enable_c_packet_size(), Set_enable_c_packet_with_back_pressure(), Set_enable_c_packet_with_idles() – Altera Avalon Verification IP Suite User Manual
Page 118: Set_enable_c_partial_valid_beats(), Set_enable_c_single_packet_per_cycle()

Chapter 5: Avalon-ST Monitor
5–9
Application Program Interface
May 2011
Altera Corporation
Avalon Verification IP Suite User Guide
set_enable_c_packet_size()
set_enable_c_packet_with_back_pressure()
set_enable_c_packet_with_idles()
set_enable_c_partial_valid_beats()
set_enable_c_single_packet_per_cycle()
Prototype:
set_enable_c_packet_size().
Arguments:
Boolean
.
Returns:
Void
.
Description:
Enables a coverage point that ensures test coverage for different size of
packets. It is disabled when packet transmission is not supported.
Prototype:
set_enable_c_packet_with_back_pressure().
Arguments:
Boolean
.
Returns:
Void
.
Description:
Enables a coverage point that ensures test coverage of packet transaction
with backpressure. It is disabled when either the
ready
signal or packet
transmission is not supported.
Prototype:
set_enable_c_packet_with_idles().
Arguments:
Boolean
.
Returns:
Void
.
Description:
Enables a coverage point that ensures test coverage of packet transaction
with idle cycles. It is disabled when packet transmission is not supported.
Prototype:
set_enable_c_partial_valid_beats().
Arguments:
Boolean
.
Returns:
Void
.
Description:
Enables a coverage point that ensures test coverage for number of
transaction with partially valid beats.
Prototype:
set_enable_c_single_packet_per_cycle().
Arguments:
Boolean
.
Returns:
Void
.
Description:
Enables a coverage point that ensures test coverage for number of
transactions that carry a single packet per cycle. It is disabled when packet
transmission is not supported.