Set_ready(), Signal_fatal_error, Signal_sink_ready_assert – Altera Avalon Verification IP Suite User Manual
Page 107: Signal_sink_ready_deassert, Signal_transaction_received
Chapter 3: Avalon-ST Sink BFM
3–7
Application Program Interface
May 2011
Altera Corporation
Avalon Verification IP Suite User Guide
set_ready()
s
signal_fatal_error
signal_sink_ready_assert
signal_sink_ready_deassert
signal_transaction_received
Prototype:
set_ready()
.
Arguments:
bit.
Returns:
void
.
Description:
Sets the value of the interface
ready
signal. To assert back pressure, deassert this
signal. The parameter
USE_READY
must be set to 1 to enable the
ready
signal.
Prototype:
signal_fatal_error
.
Arguments:
None.
Returns:
void
.
Description:
Signals that a fatal error has occurred. It terminates the simulation.
Prototype:
signal_sink_ready_assert
.
Arguments:
None.
Returns:
void
.
Description:
Signals that
sink_ready
is asserted, turning off back pressure.
Prototype:
signal_sink_ready_deassert
.
Arguments:
None.
Returns:
void
.
Description:
Signals that
sink_ready
is deasserted, turning on back pressure.
Prototype:
signal_transaction_received
.
Arguments:
None.
Returns:
void
.
Description:
Signals that the transaction has been received and queued.