Altera ALTDLL User Manual
Page 14

Chapter 2: Getting Started
2–8
Design Example: Implementing Read Paths Using Stratix III Devices
© February 2012
Altera Corporation
ALTDLL and ALTDQ_DQS Megafunctions User Guide
.
6. On the Advanced Options tab, on the DQS IN page, specify the parameters as
shown in
. These parameters configure the DQS input path of the
ALTDQ_DQS instance.
Table 2–5. Parameter Settings
Parameter
Value
RLDRAMII Mode
NONE
Number of bidirectional DQ
0
Number of input DQ
8
Number of output DQ
0
Number of stages in dqs_delay_chain
3
DQS input frequency
150 MHz
Use half-rate components
Turned off.
The design uses full-rate
memory components, so
you do not select this
option.
Use Dynamic OCT
Turned off.
Dynamic OCT is not used for
input paths.
Add memory interface specific fitter grouping assignments
Turned on.
Table 2–6. Advance Options (DQS IN)
Parameter
Sub-options
Value
Enable DQS Input Path
—
Turned on.
Enable dqs_delay_chain
—
Selected.
Advanced delay chain options
Select dynamically using
configuration registers
Turned off.
DQS delay chain
‘delayctrlin’ port source
DLL
The DQS delay-chain settings
is based on the DLL.
DQS Delay Buffer Mode
Low
Use the same mode selected
in the DLL settings.
DQS Phase Shift
9000..
Specify a 90° DQS phase shift.
The phase-shift value must
inter-relate with the selected
dqs_delay_chain stage.
Enable DQS offset control
Turned off.
Disable DQS delay fine-tuning
using offset feature.
Enable DQS delay chain
latches