beautypg.com

3 safety, 1 intended use, Section 3 – Pilz PMCprimo DriveP.06/AA0/4/0/0/208-480VAC User Manual

Page 9: Safety, Intended use, 3safety

background image

Safety

Operating Manual PMCprotego S2­2(­C)
1002529­EN­02

9

3

Safety

3.1

Intended use

The safety card PMCprotego S2­2(­C) is an expansion of the servo amplifier PMCprot­
ego D. It is designed for use in safety­related applications.

It meets the requirements for safety functions in accordance with EN 61800­5­2, with re­
gard to safe motion monitoring.

The safety card meets the requirements of EN IEC 61508 up to SIL 2 and EN ISO 13849­1
up to PL d.

The function of the safe pulse disabler is tested

}

By restarting after safety functions SS1 or STO have been triggered as a condition of
operation

or

}

By restarting after safety function SS1 has been triggered by the operator

INFORMATION

To test the safe pulse disabler through deliberate operator action, see the
section entitled "Operation", under "Testing the safe pulse disabler".

The following is deemed improper use:

}

Any component, technical or electrical modification to the servo amplifier

}

Use of the servo amplifier outside the areas described in this manual

}

Use of the servo amplifier outside the documented technical details (see chapter en­
titled “Technical Details”)

Intended use includes making the installation and wiring EMC­compliant.

Intended use also includes compliance with the

}

Operating manual for the PMCprotego D

}

Online help for the configuration tool PASconfig SDrive.

The safety card PMCprotego S2­2(­C) from Version 1.0 may only be used in conjunction
with the following servo amplifiers:

}

PMCprotego D.01 from Version 1.1

}

PMCprotego D.03 from Version 1.1

}

PMCprotego D.06 from Version 1.1

}

PMCprotego D.12 from Version 1.1

}

PMCprotego D.24 from Version 1.1

}

PMCprotego D.48 from Version 1.1

}

PMCprotego D.72 from Version 1.1